Sensorwell

060-J500-07

Model SC500, Strain gage mV/V Bridge Based Sensors, 110 Vac to 220 Vac Supply
The SC series models are self-calibrating microprocessor-based transducer signal conditioners when used with sig mod equipped transducers. Indicators are available with several different types of input channels and output channels. When used with unamplified strain gage transducers that have the signature calibration module installed, these instruments will completely self calibrate zero, span, decimal point, and engineering units automatically. Input channels are available for a variety of transducers. Each input channel includes an excitation power supply and an isolated voltage analog output.
• Unamplified pressure or load
• Pressure or load with internal voltage amplifiers
• Pressure or load with internal or external two-wire current amplifiers
• ac/ac displacement transducer
• dc/dc displacement transducer
Available output channels for the SC500 include:
• Contact relays for the two form C or three form A optional limits
• Isolated digital-to-analog voltage (0 Vdc to 5 Vdc, ±5 Vdc, 0 Vdc to 10 Vdc, ±10 Vdc)
In addition to the physical input and output channels, up to three virtual channels can be configured to assist in many potential applications.

Request now

060-J500-07

Produkt Merkmale

Kenndaten

  • Choice of transducer inputs
  • Small 1/8 DIN form factor
  • Automatic setup, calibration via sig cal
  • Shunt-cal, mV/V or known load calibration
  • Peak/valley capture
  • Optional analog output and RS-232/RS-485
  • Field selectable frequency response (up to 250 Hz) and calibration
  • Up to three virtual channels (optional)
  • CE approved

Technische Daten

Form Factor
1/8 DIN
Order Code
AE236QC,53A,58I
Number of Channels
1
Case Material
Aluminum
Input Type
Strain gage mV/V
Display Type
Vacuum fluorescent
Numeric Display Format
+999999 to -999999(0, 1, 2, 3, 4, 5 decimal places)
Digit Size - Normal Mode (H x W)
5 mm x 2,5 mm [0.2 in x 0.1 in] (with engineering units)
Digit Size - Large Mode (H x W)
10 mm x 5 mm [0.4 in x 0.2 in] (no engineering units)
Engineering Units Display
4 characters, available in normal mode only
Display Update per Second
4
Power Supply Type
ac (included with wall-mount adapter) or dc
dc Power Supply Requirements
10 Vdc to 26 Vdc @ 1A
ac Wall-Mount Adapter
Interchangeable plugs for use in the Americas, Europe, the United Kingdom, and Australia (100 Vac to 240 Vac
Voltage Range
0.5 mV/V to 21 mV/V
Isolation
500 V
Digital-to-Analog Resolution
15 bits
Frequency Response
Same as input
Temperature (Operating)
5 °C to 40 °C [40°F to 105 °F]
Temperature (Storage)
-30 °C to 90 °C [-22 °F to 195 °F]
Transducer Type
Unamplified pressure or load
Transducer Excitation
5 Vdc @ 60 mA max.
Supply Voltage
110 Vac to 220 Vac
Output
RS-232 Interface; Isolated analog output (0 Vdc to 5 Vdc)
Serial Setup and Output
Isolated RS-232 or RS-485 (factory option)
Maximum Baud Rate
38400 Baud
Quantity
2 Form C or 3 Form A (factory option)
Response Time
Same as input
Relay Energized When Signal Is
less than, greater than, inside or outside set point
Contact Rating
1 A @ 30 Vdc, 0.5 A @ 50 Vdc
Shunt Calibration
Shunt; mV/V; 2-, 3-, or 5-point known load (field selectable)
Power Requirements - Standard
100 Vac to 240 Vac or 10 Vdc to 26 Vdc
Product Dimensions
97 mm W x 48 mm H x 118 mm D [3.8 in W x 1.9 in H x 4.7 in D]
UNSPSC Code
81101713
UNSPSC Commodity
Electronic measurement and recording instrument engineering and design service
Availability
Global
Series Name
SC500

We are happy to help you!